<var id="1t7tl"></var>
<var id="1t7tl"></var><var id="1t7tl"></var>
<menuitem id="1t7tl"><dl id="1t7tl"></dl></menuitem>
<var id="1t7tl"><strike id="1t7tl"><listing id="1t7tl"></listing></strike></var>
<var id="1t7tl"></var>
<ins id="1t7tl"><noframes id="1t7tl"><menuitem id="1t7tl"></menuitem>
<cite id="1t7tl"><strike id="1t7tl"><listing id="1t7tl"></listing></strike></cite>
<del id="1t7tl"><span id="1t7tl"></span></del>
<menuitem id="1t7tl"></menuitem>
<menuitem id="1t7tl"><video id="1t7tl"><thead id="1t7tl"></thead></video></menuitem>
<var id="1t7tl"><video id="1t7tl"><thead id="1t7tl"></thead></video></var>
<thead id="1t7tl"></thead>
<var id="1t7tl"></var>
<menuitem id="1t7tl"></menuitem>
<var id="1t7tl"><strike id="1t7tl"></strike></var>
<var id="1t7tl"></var>
Language

EN

Language

查看產品系列
當前位置: Home >  > 
搜索
搜索
搜索

SMART gun locker

產品介紹
參數

Main Cabinet 1, Cabinet Size: Height 1600 × width 1000 × depth 500 mm ± 5 mm; customizable 2, Cabinet should be made of low alloy carbon steel, steel plate and its welding place tensile strength should be greater than or equal to 345 MPA. The thickness of the steel plate of the cabinet door is not less than 8 mm, and that of the steel plate of the cabinet body is not less than 6 mm. Cabinet body should be smooth and clean without burr.

Electron Gun Lock 1, intelligent electron gun lock for zinc alloy gun lock. 2. Requirements: Never Rust and can be used more than a million times. The electronic gun lock must have the anti-drilling, anti-prying function and each gun lock belt independent standby mechanism opens the way. Requirements can be through the network encryption command to open the doors of the gun cabinet, to facilitate rapid deployment in case of emergency, can double fingerprint, password combination to open the gun lock. The gun lock is required to have the function of the gun in position detection, and the gun in position sensing module adopts the two methods of mechanical + infrared detection, which can automatically detect whether the electronic gun lock is locked or not, and requires an intuitive display of the gun lock switch status, can real-time control in front of the gun cabinet mainframe and background view the status of the gun in place. 3. Network communication requires a TCPIP network encryption connection. 4. Electronic and Mechanical Double Lock Pick. 5. Individual Modular design locks require individual circuit board controls. The failure of a single electronic gun lock can be disabled without affecting the use of other electronic gun locks.

Lock Gun Position Gun position requires the use of whole row embedded installation, flexible layout, free collocation. The position of the gun should be surface treated, rust-proof and corrosion-proof. The electronic gun lock and the friction part of the gun should never be rusty, and the structure of the gun should not be damaged. The position of the gun should be fitted with a specially designed stock, which can be arranged vertically for any type of gun. It is convenient to replace the rifle butt, but it does not need to be replaced by professional tools. When the system is running normally, using mechanical lock to open can realize intelligent automatic alarm, when the leader approves, can mechanical lock to open the gun position lock, and record the time record of mechanical lock. When the mechanical key is used to open the lock, the system is required to give an alarm and a clear indication in the front-end control software.

Gun Cabinet Control System 1, Control System Requirements anti-black anti-virus capability. The front-end operating system requires ARM embedded control host, X86 architecture host is not allowed. Arm Host requires four-core chip, running the main frequency not less than 1.5 Ghz. The system uses a Linux system. The system is required to start up fast, power on to normal operation time can not be more than 16 seconds. 12.1 inch LCD touch screen. User-friendly interface. Standard Mandarin pronunciation prompts for each step. LCD Display Operation Process Information. When using fingerprint recognition, the error rejection rate should be less than or equal to 3% when the error acceptance rate is 0.001% . The gun cabinet surveillance video system uses the human body infrared near (non-human body movement) video recording function, is equipped with the intelligent non-contact infrared induction module. Equipped with high-definition camera (mounted on the gun cabinet) , the video can be stored locally and uploaded to the back-end Server. The video can be viewed locally on the gun cabinet control host or in the back-end. 1 to any person close to the cabinet body video shooting; 2 to the operator operating process video shooting.2. The cabinet video surveillance camera requires CCD chip, has the infrared high-definition night vision function, the video H264 compression coding way, Does Not Occupy the excessive network resources. System video recording requires supporting single mode and networking mode, single mode video data only stored in the local non-upload Server, effectively saving network bandwidth. In networking mode, the video data is stored in the local upload server at the same time, and double backup is realized to improve the data security. It is required that the normal communication of other business must not be affected either in stand-alone mode or in network mode.3. Electronic and mechanical double locks to open doors. Main engine + machinery (Secondary Operation) : When power failure, the system will be automatically downgraded to mechanical open. The Cabinet should be equipped with backup power supply equipment. It has automatic switching of backup power supply, creepage protector power cord, functional interface of door guard, security and networking, requirement of off-line and continuous transmission, human body proximity detection function, anti-disassembly function, cabinet sealing function, upgrade function test; Infrared trigger status display.4. BOOT TIME: ≤16s. 5, management APP FUNCTION: through the management APP for online application of firearms and ammunition, firearms and ammunition online authorization approval, and access to the smart cabinet operation log records, return of firearms and ammunition log records. 6. Night Vision Range Test: In low light environment, the camera infrared automatically turned on, the surveillance screen can be 10 meters away from the camera to see the outline of the human body. Video function verification: The video image captured by the built-in camera can be transmitted to the server for manual video recording, or when the system detects a moving target, it can be detected on the server for mobile video recording. 8, Restart Control Function Verification: The system can be restarted remotely on the server. 9. REMOTE ACCESS RECORD FUNCTION VERIFICATION: Remote Access to the online status of firearms/ammunition and firearms collection/return records is available on the server.

Colors and styles can be customized

公眾號

Service Hotline:

 

Address:重慶潤國-軍警裝備

 

Email: 335692185@qq.com

 

Fax:18623343215

公眾號

Copyright ? 2015 - 2018 test.com All Rights Reserved           渝ICP備2022002103號-1

Copyright ? 2015 - 2018 test.com All Rights Reserved

渝ICP備2022002103號-1

色综合久久天天综合观看