Full-band Radio Shield
Portable Frequency Jammer Portable Frequency Jammer consists of host, controller, control cable and antenna. AC220V power supply or Built-in rechargeable battery power. 1. TRANSMIT COVERAGE FREQUENCY: F1 Channel: (14 ~ 150) MHzF2 Channel: (150 ~ 350) MHzF3 Channel: (380 ~ 472) MHzF4 Channel: (838 ~ 880) MHzF 5 Channel: (929 ~ 962) MHzF6 Channel: (1800 ~ 1920) MHzF7 Channel: (2120 ~ 2190) MHzF8 Channel: (2297 ~ 2705) MHzF9 Channel: (5715 ~ 5832) MHz,2. Channel output:F1 Channel: 23.0WF2 channel: 41.9WF3 channel: 30.0WF4 channel: 38.1WF5 channel: 71.0WF6 channel: 64.6WF7 channel: 40.4WF8 channel: 50.0WF9 channel: 36.0W,Total weight: 40.6 KG4, number of antennas: 5 External, 4 internal. 5, blocking distance: The receiving level of Huawei MLA-AL10 is ≤-65 DBM, and the distance of the prototype is 100m, the mobile phone can not successfully dial and answer the call. Transmit Power: 395W7, number of jamming modules: With 9 jamming modules, each jamming module has its own control switch. 8, frequency setting function: The controller can be selected on the LCD display to set the frequency 9, wired control distance: 10m,10, ONE-CLICK START FUNCTION: through the host switch, one-click start host. (a) name of manufacturer or trademark; (B) type and name of equipment; (C) nature of power supply (AC, DC or AC/DC) and polarity; (d) voltage rating or voltage rating range; (e) current rating and type of Fuse Tube; (F) nature and function of terminals; (g) safety class; (h) safety warning symbol,Resistance to rubbing: The marking is not easily erasable. Resistance to electricity strength: safety precautions between the power plug or the power lead-in end of the alarm device and the exposed metal part of the housing, withstand GB16796-2009 in Table 1 of the 45 hz ~ 65 HZ AC voltage resistance test, 1 min should be no breakdown and arc phenomenon. 14. Insulation Resistance: The insulation resistance between the power plug or the leading-in end of the power supply and the exposed metal parts of the shell of the alarm equipment for safety protection, after being pretreated with moisture at a relative humidity of 91% ~ 95% and a temperature of 40 °C for 48 hours, equipment for strengthening insulation shall not be less than 5m Ω, equipment for basic insulation shall not be less than 2M ω, and equipment for Class III shall not be less than 1m ω. For equipment with operating voltage over 500V, the resistance value of the above insulation resistance shall be multiplied by a factor equal to operating voltage divided by 500V15. Leakage current: The leakage current of class I and II equipment operating conforms to table 2 in GB16796-2009, class III devices do not do leakage current testing. PERFORMANCE STANDARD: safety precautions alarm equipment, safety requirements and test methods. Q/JSRD 002-2017 Portable Frequency Jammer (enterprise standard)★ national safety precaution alarm system product Quality Supervision and Inspection Center, Ministry of Public Security and police electronic product quality inspection center
Colors and styles can be customized

公眾號
Service Hotline:

公眾號
Copyright ? 2015 - 2018 test.com All Rights Reserved 渝ICP備2022002103號-1
Copyright ? 2015 - 2018 test.com All Rights Reserved
- 業務咨詢
- 郵件聯系
- 咨詢電話 18623343215
- 返回頂部